OUR ULTIMATE POWER FACTOR MANAGEMENT PLATFORM

Our vision is to revolutionize power factor management, providing energy providers with a platform to optimize energy usage, reduce losses, and improve overall efficiency. By offering real-time data analysis, we enable precise control and monitoring of the power factor, ensuring optimal performance of electrical systems.

Key Features

Real-Time Monitoring

Real-time monitoring and analysis of power factor to reduce energy wastage.

Meter Integration

Seamless integration with energy meters for accurate data acquisition.

Remote Automation

Remote control and automation for optimized power factor correction.

Secure Communication

Secure and reliable communication between systems for uninterrupted performance.

Unified Platform

A unified platform providing detailed insights and reports on power factor management.

Join us in building the future of energy efficiency. Explore our platform to manage, control, and optimize power factor performance, and be part of a larger network of energy-conscious providers.
Power Factor Management System - Maximizing Energy Efficiency

smart-meter

APFC Control Architecture & Harmonics Mitigation

Intelligent capacitor bank switching with real-time reactive power compensation

Poor power factor in industrial plants causes severe penalty surcharges from distribution utilities, oversized transformer requirements, and excess resistive thermal losses across plant wiring.

Mirach Power Factor Management System continuously monitors active (kW), reactive (kVAR), and apparent (kVA) power in real time across all three phases. Advanced thyristor-switched capacitor (TSC) logic provides sub-cycle reactive power injection without hazardous electrical contactor inrush currents.

Target PF: 0.99 Lagging Thyristor Fast Switching (< 20ms) Detuned 7% / 14% Reactors THD Harmonic Filtering Modbus RS-485 / NB-IoT Uplink Cloud Energy Analytics

Integrated detuned reactors prevent electrical resonance with upstream transformers, safeguarding plant electronics and sensitive variable frequency drives (VFDs) from harmonic distortion.

Closed-Loop Power Factor Optimization

Autonomous closed-loop reactive power compensation in three seamless steps

STEP 01

High-Speed Metrology Sampling

Continuous 3-phase voltage, current, and phase angle tracking sampled at 128 cycles per second.

STEP 02

Microprocessor Step Switching

Microcontroller calculates optimal kVAR steps and engages thyristor capacitor switches in under 20 milliseconds.

STEP 03

Penalty Elimination & Telemetry

Power factor maintains 0.99+ unity, completely eliminating utility penalties and streaming audit logs to cloud dashboards.

Energy Efficiency ROI & Penalty Elimination

Maximize electrical system capacity and slash electricity utility bills

Financial & Energy Savings

  • Average Plant Power Factor: 0.81 → 0.99+
  • Utility Low-PF Penalty Surcharges: 100% Eliminated
  • Apparent kVA Maximum Demand Reduction: 18% - 26% Saved
  • Capital Investment Payback: Under 4 Months

Industrial Power Quality Ecosystem

Seamless integration with industrial plant SCADA and energy management platforms:

Automatic Power Factor Correction (APFC) Active Harmonic Filters (AHF) Modbus RTU / TCP Gateway kVA Demand Management ISO 50001 Energy Management Transformer Thermal Loss Reduction